Dial Gauges
Moderator: dromia
Dial Gauges
Some of the articles I have read refer to dial gauges that reach into the bore with long needles I'm not sure if that's the right description. What do you use and where should I go to buy them.
- Pippin89
- Posts: 1032
- Joined: Thu Apr 04, 2019 11:54 am
- Home club or Range: Chichester Rifle and Pistol Club
- Location: West Sussex, UK
- Contact:
Re: Dial Gauges
I think what you need is an inclined dial gauge. They normally sit at about 12° from memory. If you want accurate readings it is important that they are set at the correct angle. I normally get tooling like that from Cromwell.
Re: Dial Gauges
Finger clock.
Re: Dial Gauges
Sorry but that doesn't help.Andy wrote:Finger clock.
-
- Posts: 1154
- Joined: Fri Dec 10, 2010 3:08 pm
- Contact:
Re: Dial Gauges
Not easy to find one with a longish finger - to probe beyond the first inch of barrel. Also - if you like to work in thous - get an imperial one.
Re: Dial Gauges
Ok, I get it now. I already have one of those but the pointer is 15 centimeters at the most. And obviously it's a metric gauge.
Re: Dial Gauges
Millimeters, not centimeters. As you have probably gathered the metric system is still a mystery to me having been brought up on feet and inches.Alpha1 wrote:Ok, I get it now. I already have one of those but the pointer is 15 centimeters at the most. And obviously it's a metric gauge.
- Pippin89
- Posts: 1032
- Joined: Thu Apr 04, 2019 11:54 am
- Home club or Range: Chichester Rifle and Pistol Club
- Location: West Sussex, UK
- Contact:
Re: Dial Gauges
Metric system is the easiest think in the world! Everything works in multiples of 10! And not just that, but all the units which get used together are designed to work together. E.G. 1 millilitre of water is 1 gram, 1 joule per 1 second is 1 watt, 1 Newton per 1 metre squared is 1 Pascal.Alpha1 wrote:Millimeters, not centimeters. As you have probably gathered the metric system is still a mystery to me having been brought up on feet and inches.Alpha1 wrote:Ok, I get it now. I already have one of those but the pointer is 15 centimeters at the most. And obviously it's a metric gauge.
Compared to Imperial... 1 pint of water is 16 ounces, 1 ftlb energy per 1 seconds is 0.001818 Horsepower, 1 lbf per 1 foot squared is 0.00694 psi.
Re: Dial Gauges
The UK started to adopt the metric system in 1965 and decimalisation was 1971. I was born in 1957 so I can happily use both although my preference is metric. Oddly I still do a bit of a mental shuffle when I get into the fine tolerance stuff and will set the limits at +/- 0,01mm and then consider what that is in imperial, think yes, that will work and carry on.
Many many people a lot younger than myself will send me drawings in imperial and think I am OK with them, yet I always end up converting them to metric.
Just use whatever works for you. Denmark used to use Ells for ranging distances many years, maybe that is worth looking into further.
Many many people a lot younger than myself will send me drawings in imperial and think I am OK with them, yet I always end up converting them to metric.
Just use whatever works for you. Denmark used to use Ells for ranging distances many years, maybe that is worth looking into further.
Who is online
Users browsing this forum: No registered users and 0 guests